Genesis Leadscrew and Hydraulic Drive Systems

There are two drive systems available for the Genesis Enclosure. Listed below are the main features of each drive system.

Leadscrew Drive System


Leadscrew
  • Driven by a single-phase 2 HP motor attached to a 1" ACME screw
  • Powered by building mains power converted to 24 VDC (standard)
  • Platform travels between landings at 3 meters (10 ft) per minute
  • Six Lifting Heights up to a maximum of 3734mm (147") - floor mounted
  • Manual Emergency Lowering Handwheel (standard)
  • Battery Powered Emergency Lowering (optional)
  • Electrical Disconnect (optional)
  • Mains Power Requirement:
  • North America - 120 VAC single phase on a dedicated 20 amp circuit.
  • International - 208-240 VAC single phase on dedicated 16 amp circuit

Hydraulic Drive System


Hydraulic Drive System
  • Driven by a single-phase 3 HP hydraulic motor
  • Powered by continuous mains power with auxiliary power system (standard)
  • Platform travels between landings at 5.2 meters (17 ft) per minute
  • Seven Lifting Heights up to a maximum of 4343mm (171") - floor mounted
  • Manual Emergency Lowering
    (standard)
  • Full time battery operation (optional)
  • Mast Heater (optional)
  • Remote Drive Cabinet (optional)
  • Electrical Disconnect (optional)
  • Mains Power Requirement:
  • North America - 120 VAC single phase on a dedicated 15 amp circuit.
  • International - 208-240 VAC on a dedicated 16 amp circuit