Turning Clearances (Artira)

From Garaventapedia

Jump to: navigation, search


The space requirements of the Artira are affected by how the tube system is supported. The lift can either be mounted directly to the wall, Direct Mount, or structural support posts can be supplied Tower mount. See Attachment Methods for further information.


Artira Stair Width Clearances and Platform Projection Dimensions


Dimension Attachment Method Platform Sizes
800x 1220mm*
(31 1/2" x 48")*
800 x 1050mm
(31 1/2" x 41 3/8")
800 x 900mm
(31 1/2" x 35 3/8")
700 x 750mm
(27 1/2" x 29 1/2")
mm in mm in mm in mm in
A Direct Mount 125 4 7/8 125 4 7/8 125 4 7/8 125 4 7/8
Tower Mount 150 5 7/8 150 5 7/8 150 5 7/8 150 5 7/8
B Direct Mount 320 12 5/8 320 12 5/8 320 12 5/8 330 13
Tower Mount 345 13 5/8 345 13 5/8 345 13 5/8 355 14
C Direct Mount 1015 40 1015 40 1015 40 900 35 3/8
Tower Mount 1040 41 1040 41 1040 41 925 36 3/8
D Direct Mount 1230 48 3/8 1230 48 3/8 1230 48 3/8 1115 44
Tower Mount 1255 49 3/8 1255 49 3/8 1255 49 3/8 1140 45
E Direct Mount 1035 40 3/4 1035 40 3/4 1035 40 3/4 920 36 1/4
Tower Mount 1060 41 3/4 1060 41 3/4 1060 41 3/4 945 37 1/4
F Direct Mount 1225 48 1/4 1185 46 5/8 1145 45 1/8 1025 40 3/8
Tower Mount 1250 49 1/4 1210 47 5/8 1170 46 1/8 1050 41 3/8

Notes:

  • *Platform Size is ADA Compliant
  • Dimensions E and F includes 20mm (3/4”) running clearance and include standard ramps. Ramp extensions will increase the clearances required. Contact your local Garaventa representative or call the Garaventa Design Hot Line for more information.
  • For towers mounted to 2” x 6” wood boards on walls add 38mm (1 1/2”) to the above tower mount dimensions


Outside Radius Bends

Artira Outside Radiu Bend Clearances.png

Consult Garaventa Lift for clearances on outside radius bends.

Personal tools
Inclined Platform Lifts
LU/LA Elevators
Portable Wheelchair Lifts